Closed loop hall effect current sensors are used in measurement of Alternating and Direct Current in electrical and electronic equipments such as SMPS, UPS, AC & DC industrial drives, in process control applications like light control, heater load control etc.
SPECIFICATION
Product No
HE200T04
Nominal Input (Ipn)
200 Arms
Max Input (Ip)
± 420 A
Supply Voltage
±12 ... ± 15 V
Output @Ipn
100 mA
Bandwidth -3dB
DC - 100 kHz
Accuracy
± 0.80 %
Secondary Termination
Tab Terminals
Mounting Type
Panel
KEY FEATURES
DC, AC and pulse current measurements with galvanic isolation.